| Fixed-Position ACB | 630–6,300 A | Up to 1,000 V AC | 3 or 4 | Thermal-magnetic or electronic | Main distribution boards and industrial switchboards | Lower initial cost; simple installation; compact panel arrangement | Requires isolation and maintenance access inside the switchboard |
| Draw-Out ACB | 630–6,300 A | Up to 1,000 V AC | 3 or 4 | Electronic, often with adjustable protection | Critical facilities, data centers, hospitals, and large commercial buildings | Fast replacement, safer inspection, and reduced maintenance downtime | Higher cost; requires compatible cradle, shutters, and correct compartment dimensions |
| Thermal-Magnetic ACB | 630–4,000 A | Up to 690 V AC | 3 or 4 | Thermal overload and magnetic short-circuit release | Standard industrial and commercial power distribution | Straightforward operation; no auxiliary power normally required for basic protection | Less precise adjustment and limited monitoring compared with electronic units |
| Electronic Trip ACB | 630–6,300 A | Up to 1,000 V AC | 3 or 4 | Adjustable long-time, short-time, instantaneous, and ground-fault protection | Large facilities, high-load industrial systems, and selective-coordination projects | Precise settings, improved coordination, event recording, and measurement options | Needs correct configuration; auxiliary power and training may be required |
| Current-Limiting ACB | 800–4,000 A | Up to 690 V AC | 3 or 4 | High-speed electronic or specialized current-limiting release | Systems with high prospective short-circuit current | Can reduce let-through energy and stress on downstream equipment | Verify tested performance, peak current limitation, and coordination with downstream devices |
| Selective-Coordination ACB | 800–6,300 A | Up to 1,000 V AC | 3 or 4 | Advanced electronic trip with time-current adjustment | Critical power systems requiring continuity of service | Helps isolate faults while keeping unaffected circuits energized | Requires a complete coordination study and verified protection settings |
| Energy-Monitoring ACB | 630–6,300 A | Up to 1,000 V AC | 3 or 4 | Electronic trip with voltage, current, power, and energy measurement | Smart buildings, energy-management systems, and industrial facilities | Supports load analysis, alarm functions, and energy-efficiency programs | Check communication protocol, measurement accuracy, cybersecurity, and integration requirements |
| Maintenance-Switching ACB | 630–4,000 A | Up to 1,000 V AC | 3 or 4 | Electronic trip with maintenance mode or reduced-energy settings | Facilities where energized maintenance risk must be managed | Can help reduce arc-flash incident energy during qualified maintenance | Must be used with site procedures, risk assessment, labels, and qualified personnel |