Grade A Low-temperature | 70–90°C | Approximately 1,000–2,500 m, depending on local geothermal gradient and reservoir structure | 20–80 L/s | Low-temperature ORC using a refrigerant or hydrocarbon working fluid; recuperated systems may improve part-load performance | Approximately 7–10% of the available thermal input | Approximately 0.1–0.8 MWe, subject to flow rate and reinjection temperature | Small distributed power generation, combined heat and power, greenhouse heating, aquaculture, and district heating | Large heat exchangers may be required because of the small temperature difference. Maintaining a low reinjection temperature can improve power output but may increase scaling risk. |
Grade B Moderate-temperature | 90–120°C | Approximately 1,500–3,000 m, subject to basin geology and well completion design | 30–100 L/s | Single-stage ORC or optimized recuperated ORC; two-stage heat recovery can be used where direct heat demand is also important | Approximately 9–13% of the available thermal input | Approximately 0.3–1.8 MWe, depending on production temperature, flow, and parasitic loads | Binary power generation combined with district heating, industrial process heat, agricultural heating, and rural energy supply | Silica and carbonate scaling should be evaluated. A sealed surface heat exchanger reduces contact between geothermal brine and the turbine loop. |
Grade C Medium-temperature | 120–150°C | Approximately 2,000–3,500 m, with deeper drilling possible in areas of lower geothermal gradient | 40–120 L/s | High-performance ORC, dual-pressure ORC, or cascaded binary system; a dual-loop design can improve heat recovery across a wider temperature range | Approximately 11–16% of the available thermal input | Approximately 0.8–3.5 MWe, depending on well deliverability and the reinjection temperature target | Small- to medium-scale geothermal electricity, combined heat and power, district heating, industrial drying, and high-load thermal applications | Wellbore insulation, pressure control, corrosion protection, non-condensable gas management, and reliable reinjection are important for long-term operation. |
Grade D Upper binary range | 140–150°C | Approximately 2,500–4,000 m in areas with moderate or low geothermal gradients | 50–150 L/s | Dual-pressure ORC or cascaded ORC with a high-temperature primary loop and a lower-temperature recovery loop | Approximately 13–17% of the available thermal input | Approximately 1.2–4.5 MWe, subject to sustainable flow and net auxiliary consumption | Utility-scale binary generation at a local level, industrial power supply, district heating networks, and combined heat-and-power plants | Higher temperature improves power density, but high dissolved solids, gas content, corrosion, and mineral deposition can increase maintenance requirements. |