| General-Purpose 1:1 Isolation Transformer | Protection of control circuits, test equipment, industrial electronics, and sensitive loads from direct galvanic connection to the supply. | Single-phase or three-phase; dry-type construction is common. | Approximately 100 VA to 500 kVA, depending on phase arrangement and enclosure design. | 50 Hz or 60 Hz | 1:1 nominal ratio; custom primary and secondary voltages are available for regional systems. | Provides galvanic isolation and can reduce the propagation of common-mode electrical disturbances when properly shielded and grounded. | Rated power, input and output voltage, insulation class, dielectric strength, temperature rise, voltage regulation, enclosure rating, and terminal arrangement. | IEC 61558-1 and IEC 61558-2-4; applicable national installation and safety requirements should also be checked. |
| Step-Up or Step-Down Isolation Transformer | Adapting equipment between different voltage systems while maintaining electrical separation. | Single-phase or three-phase; often supplied as a dry-type transformer. | Approximately 500 VA to several hundred kVA. | 50 Hz or 60 Hz | Typical examples include 120/230 V, 220/110 V, 230/400 V, and other project-specific ratios. | Combines voltage conversion with galvanic isolation. The output current changes according to the voltage ratio and transformer rating. | Primary and secondary voltage tolerance, rated kVA, phase sequence, frequency compatibility, tap settings, inrush current, efficiency, and short-circuit impedance. | IEC 61558-1 and IEC 61558-2-4; local wiring rules and supply-voltage requirements must be confirmed. |
| Medical Isolation Transformer | Medical locations and patient-care areas where leakage current control and supply continuity are critical. | Usually single-phase, shielded, dry-type construction with a dedicated monitoring system where required. | Commonly approximately 2.5 kVA to 10 kVA for medical IT systems; larger project ratings may be specified. | 50 Hz or 60 Hz | Normally 1:1 or a project-defined ratio suitable for the local medical power system. | Designed for low leakage current and safe separation. It does not replace equipotential bonding, protective measures, or an insulation-monitoring system. | Leakage current, insulation-monitoring compatibility, temperature rise, overload capability, noise level, medical-location classification, and alarm interfaces. | IEC 61558-2-15 and IEC 60364-7-710; additional healthcare electrical requirements may apply by country. |
| Control Isolation Transformer | Industrial control panels, automation systems, contactor circuits, PLC inputs, and machine-control power supplies. | Most commonly single-phase; compact dry-type units are widely used. | Approximately 50 VA to 10 kVA. | 50 Hz or 60 Hz | Common control voltages include 24 V, 48 V, 110 V, 120 V, 220 V, and 230 V, subject to the selected design. | Helps separate control circuits from the power circuit and can improve control-circuit reliability during supply disturbances. | Continuous VA rating, short-term inrush capacity, control-circuit fuse coordination, output voltage regulation, mounting method, and ambient temperature. | IEC 61558-1 and IEC 61558-2-2; machinery and control-panel requirements may also apply. |
| Three-Phase Industrial Isolation Transformer | Manufacturing equipment, process lines, motor systems, data-center auxiliary systems, and industrial distribution. | Three-phase, dry-type or liquid-filled depending on rating, environment, and installation requirements. | Approximately 3 kVA to several MVA. | 50 Hz or 60 Hz | Common configurations include delta-wye, wye-delta, delta-delta, and 1:1 three-phase isolation. | Provides phase-system separation and may establish a separately derived secondary system. Vector group affects phase displacement and system compatibility. | kVA rating, vector group, impedance, neutral availability, grounding method, sound level, cooling class, temperature rise, enclosure, and harmonic loading. | IEC 60076 series and IEC 61558 where applicable to the transformer design. |
| Electrostatic-Shielded Isolation Transformer | Instrumentation, laboratory equipment, communication systems, audio systems, and sensitive electronic loads. | Single-phase or three-phase; includes a conductive shield between primary and secondary windings. | Approximately 500 VA to 500 kVA. | 50 Hz or 60 Hz | Usually 1:1, although step-up and step-down ratios are also available. | Designed to reduce capacitive coupling of common-mode high-frequency noise. Shield effectiveness depends on correct bonding and installation. | Shield construction, shield-to-ground connection, capacitance between windings, common-mode attenuation, normal-mode noise performance, and grounding instructions. | IEC 61558-1 and IEC 61558-2-4; electromagnetic compatibility requirements should be evaluated for the complete installation. |
| Toroidal Isolation Transformer | Low-noise electronic equipment, laboratory instruments, medical equipment, audio systems, and compact power supplies. | Usually single-phase with a toroidal magnetic core and separate primary and secondary windings. | Approximately 50 VA to 10 kVA, with larger designs available for specialized applications. | 50 Hz or 60 Hz | 1:1, step-up, or step-down ratios. | Typically offers compact size, low audible hum, and low stray magnetic field compared with many conventional laminated-core designs; inrush current can be relatively high. | Inrush-current limiting, mounting hardware, thermal protection, regulation, insulation system, winding separation, noise level, and mechanical restraint. | IEC 61558-1 and the applicable part of the IEC 61558-2 series. |
| Harmonic-Mitigating Isolation Transformer | Systems with high levels of triplen harmonics from non-linear loads such as switch-mode power supplies, computers, and electronic lighting. | Usually three-phase with a phase-shifting winding arrangement, commonly selected to manage zero-sequence harmonic currents. | Approximately 15 kVA to several hundred kVA. | 50 Hz or 60 Hz | Often near 1:1, with a specified vector group and phase displacement. | Can reduce the transfer of selected harmonic components and limit the effect of certain load-generated currents when correctly matched to the system. | Harmonic spectrum, K-factor or equivalent thermal design data, vector group, neutral current capacity, impedance, temperature rise, and actual load profile. | IEC 60076 series; power-quality and installation requirements should be reviewed for the application. |
| Drive or Converter Isolation Transformer | Variable-frequency drives, rectifiers, converters, motor systems, and industrial power-electronic equipment. | Typically three-phase; may use a dedicated phase-shifting or rectifier-compatible winding arrangement. | Approximately 10 kVA to several MVA. | 50 Hz or 60 Hz supply frequency | 1:1, step-up, or step-down; phase-shifted configurations are selected according to the converter topology. | Provides isolation and can help manage commutation effects, harmonic currents, and fault-current coordination in power-electronic systems. | Converter pulse number, harmonic duty, short-circuit impedance, motor-starting or drive inrush, thermal duty cycle, cooling, vector group, and insulation coordination. | IEC 60076 series and applicable power-drive, machinery, and installation standards. |
| Portable Isolation Transformer | Temporary worksites, field service, maintenance operations, laboratories, and portable test equipment. | Normally single-phase in a protected enclosure with integral cable, plug, socket, or circuit protection. | Approximately 300 VA to 5 kVA. | 50 Hz or 60 Hz | Usually 1:1; regional input and output configurations vary. | Provides localized electrical separation for portable equipment. It must not be used as a substitute for required residual-current protection or site safety procedures. | Ingress protection, impact resistance, carrying method, earth continuity, overload protection, cable length, socket standard, weight, and inspection requirements. | IEC 61558-1 and applicable national requirements for portable electrical equipment and temporary installations. |