| 1 | Thermal-Magnetic MCCB | 3P | 415–480 V AC | 100–250 A | 25–36 kA at rated voltage | IP55–IP66 enclosure | IEC 60947-2; UL 489 where applicable | Outdoor distribution panels, commercial buildings, pump stations | Confirm the short-circuit rating at the actual installation voltage. |
| 2 | High-Frame MCCB | 3P or 4P | 400–690 V AC | 400–630 A | 36–50 kA at rated voltage | IP55–IP66 enclosure | IEC 60947-2; UL 489 where applicable | Industrial feeders, outdoor transformers, heavy-duty machinery | Use adjustable long-time, short-time, and instantaneous protection when coordination is required. |
| 3 | Miniature Circuit Breaker | 1P, 2P, 3P, or 4P | 230/400 V AC | 6–63 A | 6–10 kA | IP65–IP66 enclosure | IEC 60898-1; IEC 60947-2 for industrial versions | Lighting, socket outlets, small control circuits, garden and utility panels | Select B, C, or D tripping characteristics according to inrush current. |
| 4 | RCBO with Overcurrent and Earth-Leakage Protection | 1P+N or 2P | 230 V AC | 6–40 A | 6–10 kA | IP65–IP66 enclosure | IEC 61009-1 | Outdoor outlets, fountains, irrigation controls, temporary power | A 30 mA residual-current setting is commonly used for additional personal protection. |
| 5 | Four-Pole MCCB with Neutral Switching | 4P | 400–415 V AC | 16–160 A | 25–36 kA at rated voltage | IP55–IP66 enclosure | IEC 60947-2 | Generator changeover panels, outdoor HVAC and utility distribution | Verify whether the neutral pole is switched only or also protected. |
| 6 | Photovoltaic DC MCB | 2P or 4P | 500–1,000 V DC | 10–63 A | 6–10 kA DC | IP65–IP66 solar enclosure | IEC 60947-2; IEC 60898-2 where applicable | PV string and combiner boxes, rooftop solar arrays | Use a breaker specifically tested for DC interruption and the required polarity arrangement. |
| 7 | Photovoltaic DC MCCB | 2P, 3P, or 4P | 1,000–1,500 V DC | 125–400 A | 20–50 kA DC, configuration-dependent | IP55–IP66 enclosure | IEC 60947-2; relevant photovoltaic installation requirements | Solar inverter inputs, utility-scale PV combiner and feeder equipment | Check the tested DC pole configuration, derating, and maximum series voltage. |
| 8 | Battery-System DC MCCB | 2P or 3P | 250–1,000 V DC | 100–600 A | 10–35 kA DC | IP54–IP66 enclosure | IEC 60947-2; applicable battery-storage installation codes | Energy-storage systems, battery cabinets, telecom backup power | Select a continuous-current rating that includes battery discharge and ambient-temperature derating. |
| 9 | Motor Protection Circuit Breaker | 3P | 400–690 V AC | 1.6–100 A | 10–25 kA at rated voltage | IP55–IP66 enclosure | IEC 60947-4-1 | Outdoor fans, pumps, compressors, agricultural machinery | Set the overload range to the motor nameplate current and coordinate with the contactor. |
| 10 | Air Circuit Breaker for Outdoor Switchboards | 3P or 4P | 400–690 V AC | 630–3,200 A | 50–100 kA at rated voltage | IP54–IP65 outdoor switchboard | IEC 60947-2; IEC 61439 for assemblies | Main incomers, large generators, data-center and utility switchboards | The complete outdoor assembly must control moisture, condensation, clearance, and temperature. |